Home / متفرقه / مقاله Effect of Inlet Air Cooling by Absorption Chiller and Fog Cooling Method on Gas Turbine Performance در word

مقاله Effect of Inlet Air Cooling by Absorption Chiller and Fog Cooling Method on Gas Turbine Performance در word

برای دریافت پروژه اینجا کلیک کنید

 مقاله Effect of Inlet Air Cooling by Absorption Chiller and Fog Cooling Method on Gas Turbine Performance در word دارای 12 صفحه می باشد و دارای تنظیمات در microsoft word می باشد و آماده پرینت یا چاپ است

فایل ورد مقاله Effect of Inlet Air Cooling by Absorption Chiller and Fog Cooling Method on Gas Turbine Performance در word  کاملا فرمت بندی و تنظیم شده در استاندارد دانشگاه  و مراکز دولتی می باشد.

این پروژه توسط مرکز مرکز پروژه های دانشجویی آماده و تنظیم شده است

توجه : در صورت  مشاهده  بهم ريختگي احتمالي در متون زير ،دليل ان کپي کردن اين مطالب از داخل فایل ورد مي باشد و در فايل اصلي مقاله Effect of Inlet Air Cooling by Absorption Chiller and Fog Cooling Method on Gas Turbine Performance در word،به هيچ وجه بهم ريختگي وجود ندارد


بخشی از متن مقاله Effect of Inlet Air Cooling by Absorption Chiller and Fog Cooling Method on Gas Turbine Performance در word :

سال انتشار: 1386

محل انتشار: پنجمین کنگره بین المللی مهندسی شیمی

تعداد صفحات: 12

نویسنده(ها):

Mohammad Javad Shafaei – Department of petroleum Engineering Petroleum University of Technology
Mahmoud khoshbakht – Associated Professor Department of Petroleum engineering Petroleum University of Technology

چکیده:

Gas turbine performances are directly related to site conditions. In recent years, inlet air cooling systems have been introduced to control air temperature at compressor inlet, resulting in an increase in power and efficiency. In this paper, the dependence of outside conditions for a simple gas turbine is studied, using absorption chiller and fog cooling method as inlet air cooling systems. A computer program in FORTRAN environment developed for this purpose with simultaneously calculations. We used, as case study, a simple plant equipped with one frame B gas turbine. This program is developed to consider effect of blade cooling on gas turbine performance. Effect of off-design condition on gas turbine performance exactly is considered. It was found that inlet air cooling with absorption chiller has great positive influence on power and less on efficiency of the gas turbine plant. Fog cooling method is more suitable for hot and dry conditions and has great positive influence on power and efficiency but in humid places, it is not applicable.

برای دریافت پروژه اینجا کلیک کنید

About admin

Check Also

مقاله بررسی میزان سم دیازینون در رسوب رودخانه پلرود و گیاه آقطی در word

 مقاله بررسی میزان سم دیازینون در رسوب رودخانه پلرود و گیاه آقطی در word دارای …